CruzPro ER-1 External Relay switch enables you to switch ON/OFF loads of up to ten amps using the external alarm outputs of your CruzPro digital gauges.


ER-1

Download User's Manual PDF

CruzPro ER1 External 10 amp Relay



Specifications

Supply Voltage:
10.0 to 30.0 VDC 0.035 amps max.

Relay Contacts:
10 Amps maximum.
Both NO (Normally Open) and NC (Normally Closed) contacts.

Operating temperature:
0 to 50 deg Celsius ( 32 to 122 deg Fahrenheit).

Size:
50 x 35 x 30 mm (2 x 1.4 x 1.2 inch)

Control:
Low power +3.5 to +12 VDC switches the relay ON.

Input Resistance (Control Line):
10K Ohms minimum.


ER-1 External Relay Switch

The ER-1 External Relay switch can be connected to the "external alarm" output of many of the CruzPro instruments and used to switch high current loads with the normally open and normally closed relay contacts.

The input resistance of the control line is 10,000 ohms minimum and a Control voltage of between +3.5 to +12 VDC can be used to switch the relay from OFF to ON.

The external relay switch is powered by 12 or 24VDC and typically draws only 0.035 amps when the relay is switched ON and almost no power when the relay is switched OFF.


ER-1 Connection Diagram to CruzPro 25/30/35/55/60 and 65 series instruments


ER-1 Connection Diagram





Connecting the CruzPro ER-1 External Relay module to 110mm instruments

Click here to go to ER-1 page

ER-1 External Relay Connection Diagram




Connecting the CruzPro DI-31 light sensor to the ER-1 External Relay module to make a night activated anchor light control